Industry: hazardous waste disposal
Processing objects: domestic sewage + medical wastewater
Treatment pollutants: COD, SS, ammonia nitrogen, total nitrogen, total phosphorus, BOD5, heavy metals
Treatment capacity: domestic sewage (1 m3 / h) + pharmaceutical wastewater (6 m3 / h)
Treatment process: domestic sewage: hydrolysis acidification tank + anoxic tank + aerobic tank + MBR membrane tank
Pharmaceutical wastewater: regulating tank + air flotation tank + reduction tank + coagulation sedimentation tank + quartz sand filter
Reclaimed water reuse: Ultrafiltration + reverse osmosis
Reference discharge standard: quality of industrial water for urban wastewater recycling (GB / T 19923-2005)
Shanghai integrated wastewater discharge standard (DB31 / 199-2018)